Page 7 of 51
The wireless and wired (RS485) connections are mutually exclusive, therefore the PVI-DESKTOP
cannot be used in both configurations and the communication channel must always be chosen.
When the use wireless communication is chosen, it is absolutely necessary that every field
inverter has the PVI-Radiomodule installed; it is not possible to use one PVI-Radiomodule and
connect the other inverters to each other via RS485.
2.2 POSSIBLE USE
2.2.1 POSSIBLE CONNECTION TO INVERTERS
• RS485 (cable length up to approx. 1000m, a maximum of 6 inverters)
• Radio (approx. up to 300m in the open/obstacle free, maximum of 6 inverters)
The list of inverters having limitations in using the PVI-DESKTOP , is summarized in the following table:
INVERTER
model
PVI-Radiomodule
compatibility
RS485
compatibility
Notes
PVI-6000 Yes (see note) YES Inverters manufactured before the
week 32/09 require a firmware
upgrade.
PVI-5000 YES YES Inverters manufactured before the
week 32/09 require a firmware
upgrade.
PVI-3600 Indoor YES (see note) YES From the FW 11 version of the PVI-
RADIOMODULE (units manufactured
after the week 25/10).
PVI-2000 Indoor YES (see note) YES From the FW 11 version of the PVI-
RADIOMODULE (units manufactured
after the week 25/10).
PVI-3600 Outdoor
NO YES N/A
PVI-2000 Outdoor
NO YES N/A
All other inverter models (PVI-3.0/3.6/4.2/10.0/12.5-OUTD) in all different versions, there are
no compatibility issues.
2.2.2 OPERATIVE SYSTEMS COMPATIBLE FOR PC CONNECTION
• Windows XP 2002 version(Home and Professional), Service Pack 3
• Windows 2000
• Windows Vista 32bit
• Windows Vista 64bit
• Windows 7 32bit
• Windows 7 64bit