LIUSK8B00_eng-01AUTEC
39
11 Malfunction signalled by the Transmitting Unit
The table below lis malfunctions that are signalled by LEDs on the Transmitting Unit and the
solution to those malfunctions.
If the problem persis after attempting the suggeed solution, contact the support service of
the Machine Manufacturer.
Signals Possible reasons Solutions
The green LED is eady on.
The Transmitting and Receiving
Unit do not communicate.
Bring the Transmitting Unit close
to the Receiving Unit until the
green LED blinks quickly (if the
signal doesn't change, check that
the Receiving Unit is powered),
then activate and release
START. When START is
released, the green LED arts
blinking slowly.
The green LED repeats the
sequence: two blinks and a
pause.
The working range of the remote
control has been exceeded for
more than 20 seconds.
Bring the Transmitting Unit close
to the Receiving Unit, then
activate and release START.
When START is released, the
green LED arts blinking slowly.
The green LED repeats the
sequence: three blinks and a
pause.
The Transmitting and Receiving
Unit do not communicate.
Bring the Transmitting Unit close
to the Receiving Unit until the
green LED blinks quickly (if the
signal doesn't change, check that
the Receiving Unit is powered),
then activate and release
START. When START is
released, the green LED arts
blinking slowly.
The green LED blinks fa. Temporary loss of radio link.
Bring the actuators related to
movement commands to the re
position, then activate and
release START. When START is
released, the green LED arts
blinking slowly.