Software Operations
21 | P a g e
Troubleshooting the RoboCrib using the “Console” Button
- At the RoboCrib, insert the badge number and PIN. (Note: At least one employee must be setup as a supervisor
in the AutoCrib software.)
- Select the Console button.
- To call a bin, type FET BBB P (B is for Bin Number, P is for Baffle Position). i.e. FET 21L 3 will call bin 21L and
set the baffle position for a fourth pie.
o Baffle Positions (P) are as follows:
(1) = twelfth pie
(2) = sixth pie
(3) = fourth pie
(4) = third pie
(5) = half or full pie
- Once the bin has been positioned in front of the doors, you must open the door. LON DD (D is for door number).
I.e. LON 15 will open door 15.
- An invalid bin number will return an error (E2). If the tray configuration is unknown, please refer to the number
scheme provided at the time of installation.
- Other commands that can be used:
o RSA (Report Status All): If system is calibrated and all doors are closed, the system will report back
“OK”. If a door is open, the system will report back “DO”.
o CAL M or CAL L: moves the main platter or LSP one complete clockwise revolution.
o TST M or TST L: moves the main platter or LSP one complete counter clockwise revolution.
o To view more controller commands, please reference Appendix I.