Standard maintenance change bin door lubricating procedures. In effort to reduce the number of
difficulties in closing bin doors as well as reducing the number of bin doors that intermittently do
not open when actuated.
The following procedure is recommended as periodic maintenance of your system. About every
three months or more often if your machine is in a dusty / dirty Environment. PLEASE NOTE: THIS
PROCEDURE SHOULD BE PREFORMED PRIOR TO CONTACTING TECHNICAL SUPPORT FOR A STICKY
DOOR PROBLEM
Step 1. Remove the Door Assembly front panel from the machine
Step 2. Remove the individual latch covers. This will expose the door actuation mechanism.
Step 3. Using a can of WD-40 or LPS with the red application tube installed in the spray nozzle ā
lubricate the mechanism in the areas show on the attached drawing.
Step 4. Check proper alignment of the encoders
Step 5. Reinstall covers