3. In the work area, click the Web/Telnet tab.
4. Click the arrow on the Web/Telnet Switch Password Type box.
5. Select a password type from the list.
6. Type the password for read-only access in the Read-Only Stack Password box.
7. Type the same password for read-only access in the Re-enter to verify box.
8. Type the password for read-write access in the Read-Write Switch Password
box.
9. Type the same password for read-write access in the Re-enter to verify box.
10. On the toolbar, click Apply.
Variable definitions
Variable Value
Web/Telnet Stack Password Type Specifies the type of the password to use.
Values include:
• none—disables the password
• Local Password— uses the locally defined
password for Web and Telnet access.
• RADIUS Authentication— uses RADIUS
password authentication for Web and
Telnet access.
• TACACS Authentication— uses TACACS
+ authentication, authorization, and
accounting (AAA) services authentication
for Web and Telnet access.
Read-Only Stack Password Specifies the read-only password for stack or
switch access. The maximum length of the
password is 15 characters.
Read-Write Switch Password Specifies the read-write password for stack
or switch access. The maximum length of the
password is 15 characters.
Setting user access limitations using EDM
Quick Start Configuration for Avaya ERS 4000 Series November 2013 31