Procedure
1. Enter Global Configuration mode in ACLI:
enable
configure terminal
2. To enable Telnet remote access, enter the following command at the command
prompt:
telnet-access enable
3. To enable SSH remote access, enter the following command at the command
prompt:
ssh
4. To enable SNMP remote access, enter the following command at the command
prompt:
snmp-server enable
5. To enable Web Page remote access, enter the following command at the command
prompt:
web-server enable
Example
The following is an example of enabling Telnet remote access:
4850GTS-PWR+>enable
4850GTS-PWR+#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
4850GTS-PWR+(config)#telnet-access enable
4850GTS-PWR+(config)#
Using telnet to log on to the device
About this task
Use Telnet to log on to the device and remotely manage the switch.
Procedure
1. From a PC or terminal, start a Telnet session:
telnet <IPv4_address>
• where <IPv4_address> is the IP address of the switch. The ERS 4000 standalone
units use the default IP address of 192.168.1.1 if the switch does not get its IP
address from another source.
Configuring the switch using ACLI
42 Quick Start Configuration for Avaya ERS 4000 Series November 2013
Comments? infodev@avaya.com