Table 16: clock summer-time zone command
Variable Value
date Indicates that daylight savings time you set to start and end
on the specified days every year.
day Day to start daylight savings time.
month Month to start daylight savings time.
year Year to start daylight savings time.
hh:mm Hour and minute to start daylight savings time.
day Day to end daylight savings time.
month Month to end daylight savings time.
year Year to end daylight savings time.
hh:mm Hour and minute to end daylight savings time.
offset Number of minutes to add during the summer time.
zone The time zone acronym to be displayed when daylight
savings time is in effect. If it is unspecified, it defaults to the
time zone acronym set when the time zone was set.
Configuring clock
In addition to SNTP time configuration, a clock provides the switch with time information. This
clock provides the switch information in the instance that SNTP time is not available.
About this task
Use the clock source command to set the time source for the switch.
Procedure
1. Enable Global Configuration mode in ACLI:
enable
configure terminal
2. Set the clock source for the switch.
clock source {ntp | sntp | sysUpTime }
Related topics:
Variable definitions on page 40
Configuring clock
Quick Start Configuration for Avaya ERS 4000 Series November 2013 39