clock summer-time zone date day month year hh:mm day month
year hh:mm [offset]
5. Save the changed configuration.
Example
Setting time zone example
4850GTS-PWR+>enable
4850GTS-PWR+#configure terminal
4850GTS-PWR+(config)#clock time-zone PST -8
This command sets the time zone to UTP minus 8 hours and the time zone will be displayed
as "PST."
Setting daylight savings time example
4850GTS-PWR+(config)#clock summer-time BST date 28 Mar 2013 2:00 30
Aug 2013 15:00 +60
This command sets the daylight savings time to begin at 02:00 on March 28, 2013 and end on
August 30th, 2013 at 15:00. The change to daylight savings moves the clock forward by 60
minutes and "BST" will be displayed as the time zone acronym. These changes to and from
daylight savings time will happen automatically.
Variable definitions
Use the data in the following table to use the clock time-zone command.
Table 15: clock time-zone command
Variable Value
zone Time zone acronym to be displayed when showing system
time (up to 4 characters).
hours Difference from UTC in hours. This can be any value
between -12 and +12.
minutes Optional: This is the number of minutes difference from
UTC. Minutes can be any value between 0 and 59.
Use the data in the following table to use the clock summer-time zone command.
Configuring the switch using ACLI
38 Quick Start Configuration for Avaya ERS 4000 Series November 2013
Comments? infodev@avaya.com