EasyManua.ls Logo

Avaya 4000 Series - Incorrect PVID; Incorrect PVID recovery tree

Avaya 4000 Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Variable definitions
The following table describes the optional parameters you can enter with the show boot
[diag] [image] command.
Variable Value
diag Displays only information for the agent load.
image Displays only information for the image load.
Important:
When the currently loaded and operational software status is displayed for a stack, the unit
number is replaced by the word All.
Displaying local alarms
View local alarms to monitor alarm conditions.
About this task
Local alarms are raised and cleared by applications running on the switch. Local alarms are
an automatic mechanism run by the system that do not require any additional user
configuration. The raising and clearing of local alarms also creates a log entry for each event.
Check alarms occasionally to ensure no alarms require additional operator attention.
Procedure
1. Enter Global Configuration Mode:
enable
configure terminal
2. To display local alarms, enter the following command at the command prompt:
show rmon alarm
Verification
56 Quick Start Configuration for Avaya ERS 4000 Series November 2013
Comments? infodev@avaya.com