Figure 2: Job aid
To install the ESD discharge cable, perform this procedure.
1. Connect the ground lug on the ESD discharge cable to a safe and suitable earth ground.
2. Connect all RJ-45 cable connectors to the female RJ-45 connector of the ESD discharge
cable for at least 5 seconds, and then connect each RJ-45 cable connector to the switch.
3. Leave cables connected to the networking equipment. After you connect cables to
networking equipment, the cables do not build up charge.
Environmental requirements
The following table provides the environmental requirements for the individual switches in this
series. Ensure that the area where you install the switch and where it operates meets these
requirements.
Table 7: Avaya Virtual Services Platform 4000 environmental requirements
Environmental requirement Avaya Virtual Services Platform 4000 models
Operating Temperature 0°C to 70°C (32°F to 104°F), continuous operation
Storage Temperature –40°C to 85°C (-13°F to 158°F)
Operating and Storage Humidity 0 to 95 percent noncondensing
Maximum Operating Altitude 3,048m (10 000 feet) above sea level
Altitude 0 to 3,048m (0 to 10,000ft) above sea level
Storage Altitude 0 to 12,192m (0 to 40,000ft) above sea level
Acoustic Noise Less than or equal to 45 db at 35°C and less than or equal to 57 db at
50°C. The temperature is allowed to have ±3.5°C deviation around the
threshold of 35C, (measurement methods based on ISO 7779).
Installing the Avaya VSP 4000 4450GTX-HT-PWR+
18 Installing the Avaya Virtual Services Platform 4000 VSP4450GTX-HT-PWR+ August 2014