Connect AC power
This section explains power cord specifications and how to connect AC power.
Power cord specifications
To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 15: International power cord specifications
Country and Plug Specification Specifications Typical Plug
Continental Europe:
CEE7 standard VII male plug
Harmonized cord (HAR marking on the outside of the cord
jacket to comply with the CENELEC Harmonized
Document HD-21)
220 or 230VAC
50 Hz
Single phase
United States of America, Canada, and Japan:
NEMA5-15P male plug
UL-recognized (UL stamped on cord jacket)
CSA-certified (CSA label secured to the cord)
100 or 120VAC
50–60 Hz
Single phase
United Kingdom:
BS1363 male plug with fuse
Harmonized cord
240VAC
50 Hz
Single phase
Australia:
AS3112-1981 male plug
240VAC
50 Hz
Single phase
Danger:
Using power cords with a proper grounding path
Use only power cords that have a grounding path. Without a proper ground, a person who
touches the switch is in danger of receiving an electrical shock. Lack of a grounding path to the
switch can result in excessive emissions. For a translation of this statement, see Translations of
safety messages on page 36.
Connect AC power
August 2014 Installing the Avaya Virtual Services Platform 4000 VSP4450GTX-HT-PWR+ 29
Comments? infodev@avaya.com