3. Slide the transceiver from the module slot.
4. If the transceiver does not slide easily from the module slot, use a gentle side-to-side rocking
motion while firmly pulling the transceiver from the slot.
5. Attach a dust cover over the fiber-optic bores and store the transceiver in a safe place until
you need it.
Important:
Discard transceivers in accordance with the proper laws and regulations.
RJ-45 connector pin assignments
The following section describes the connector pin assignments for the RJ-45 connectors in the
Avaya Virtual Services Platform 4000.
Console port pin assignments
The following table describes the console port pin assignments in the Avaya VSP 4000.
Important:
Avaya VSP 4000 supports only CLI Quickstart use on the console port.
Table 9: DB–9 Console port pin assignments
Connector Pin Number Signal
1 Carrier detect (not used)
2 Transmit Data (TXD)
3 Receive Data (RXD)
4 Data terminal ready (not used)
5 Signal ground (GND)
6 Not used
Installing the Avaya VSP 4000 4450GTX-HT-PWR+
24 Installing the Avaya Virtual Services Platform 4000 VSP4450GTX-HT-PWR+ August 2014