Installing the Avaya Virtual Services Platform 4000 on a
table or shelf
You can install a single Avaya VSP 4000 switch on any flat surface. The surface must support the
combined weight of the switch and attached cables (from 15 and 20 pounds [7 to 9 kilograms]).
To install an Avaya VSP 4000 on a table or shelf, perform this procedure.
1. Attach the included rubber footpads on the bottom of the switch at the locations indicated.
2. Set the switch on a table or shelf as illustrated below. Allow at least 2 inches (5.1
centimeters) on each side for proper ventilation and at least 5 inches (12.7 centimeters) at
the back for power cord clearance.
Installing the Avaya Virtual Services Platform 4000 in an
equipment rack
To install an Avaya VSP 4000 switch in an equipment rack, perform this procedure.
Installing the Avaya VSP 4000 4450GTX-HT-PWR+
20 Installing the Avaya Virtual Services Platform 4000 VSP4450GTX-HT-PWR+ August 2014