3. Insert and tighten the rack-mount screws.
Cable requirements for the Avaya Virtual Services
Platform 4000
The following table describes the cables required for an Avaya Virtual Services Platform 4000
4450GTX-HT-PWR+ switch.
Table 8: Switch cable requirements
Required Cable Description
10/100/1000Base TX Ports The interconnect cabling must conform to the Cat5e, Cat6, or Cat6e
specification of the Commercial Building Telecommunications Cabling
Standard, ANSI/TIA/EIA 568-B fitted with an RJ-45 Module jack.
10/100Base TX Ports The interconnect cabling for 10BaseT Ethernet must conform to Cat3,
Cat4, Cat5 (or better) UTP cabling for distances up to 100 meters.
The interconnect cabling for 100BaseTX Fast Ethernet must conform
to Cat5 (or better) UTP cabling for distances up to 100 meters.
100BaseFX Ports The interconnect cabling must conform to 50/125 or 62.5/125 micron
multimode fiber-optic cabling for distances up to 3 kilometers.
Console Port Varies depending on the user device. The VSP 4000 has an RJ-45
female connector, so a serial cable with RJ-45 connectors, or a serial
Installing the Avaya VSP 4000 4450GTX-HT-PWR+
22 Installing the Avaya Virtual Services Platform 4000 VSP4450GTX-HT-PWR+ August 2014