Maintenance Object Repair Procedure
555-233-142
8-940 Issue 1 May 2002
Table 8-395. Test #885 Private Loop-Around Tests
Error
Code
Test
Result Description / Recommendation
1006,
1137
ABORT Packet Interface circuit is out of service, so normal maintenance tests do not
run on that circuit.
1. Enter reset packet-interface Uc to reset the Packet Interface circuit.
For further action, see the procedures in Table 8-394 on page 8-938 for the
Packet Interface Reset test (#889).
1334 ABORT The Packet Interface circuit’s command queue is full. This should be a
temporary condition caused by a high rate of commands being sent to a Packet
Interface circuit. Continued operation with a full command queue will cause a
system WARM restart that may escalate to more severe restart levels.
1. Retry the command at 10-second intervals up to 5 times.
1335 ABORT Internal IPSI error. The Packet Interface circuit is on the standby IPSI, so this
test is not allowed to execute.
1. To run this test on the standby Packet Interface, enter set
ipserver-interface Uc to activate it.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABORT Internal system error
1. Retry the command.
NO
BOARD
The IPSI circuit pack’s Packet Interface is assigned, but is not detected as
being physically present.
1. If the IPSI circuit pack is present, replace it.
2. If not, insert a TN2312 IPSI circuit pack in the assigned slot, and rerun the
test.
Continued on next page