TIE-DS1 (DS1 Tie Trunk)
Issue 1 May 2002
8-1147555-233-142
DS1 Tie Trunk Seizure Test (#136)
The DS1 Tie Trunk Seizure test is run to verify the trunks signaling capability.
The test is composed of two parts. The first part queries the circuit pack for the
following errors: Loss of Signal, Red alarm, Blue alarm, Yellow alarm, and
Hyperactivity alarm. The second part of the test is performed by sending a
seizure message to the DS1 Interface circuit pack and expecting an active reply
by the DS1 Interface circuit pack. If maintenance software does not receive any
reply and the timer expires, the test fails. Once the active message is received, a
dial pause message is sent to the DS1 Interface circuit pack. If the DS1 Interface
circuit pack replies with a dial pulse tone message when the far end responds to
the seizure, then the DS1 tie trunk Seizure test passes. If the far end does not
respond to the seizure and the timer expires, and the DS1 Interface circuit pack
sends a reorder message back to the maintenance software, then the test fails.
PASS Trunk translation has been updated successfully. The current trunk states kept
in the DS1 Interface circuit pack and switch software are consistent. If the
trunk is busied out, the test does not run but returns a PASS. To verify that the
trunk is in-service:
1. Enter the status trunk command to verify that the trunk is in-service. If the
trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to step 2.
2. Enter the release trunk command to put the trunk back into in-service.
3. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the boards translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, check to see
that there is a valid board inserted.
Table 8-488. Test #36 Audit and Update Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page