Maintenance Object Repair Procedure
555-233-142
8-1148 Issue 1 May 2002
This second part of this test cannot be run on a trunk if one of the following cases
is true:
1. The trunk direction is administered as an incoming only trunk.
2. The trunk is the 24
th
port on a DS1 Interface circuit pack which is
administered using 24
th
common-channel signaling.
3. The trunk has been seized by a normal trunk call.
4. The trunk is administered with maintenance test disabled.
5. The outgoing signal type of the trunk is either automatic or immediate-start.
6. This test always passes if the associated board is the TN802 IP trunk
circuit pack.