7 — Appendices
7 - 30 Service Instructions RP-A301CE/RP-A351CE/RP-A355CE
Exit Test
Exit test: it visualises the exit status of the control
signals; press ENT to enter the functions:
Blade rotation: pressing the 1 button the blade
starts.
Blade rotation and feed carriage moving
forward: pressing the 2 button the blade starts
and the carriage advances to the cutting travel
end.
Blade rotation and feed carriage moving back:
pressing the 3 button the blade starts and the
carriage goes back to the travel end near the
operator side.
Feed carriage cycle: pressing the 4 button the
carriage makes a complete working cycle.
Finished the control operations, press ESC.
Initialisation
This function allows to initialise with default
values all the data of the E2PROM which is
protected by a password and it is used during the
Initialisation construction.