3 — Operation
3 - 20 Service Instructions RP-A301CE/RP-A351CE/RP-A355CE
3.1.7 Blade sharpening A301CE
If the cut is not adequate, the blade must be
sharpened. The intervals between the
sharpening operations depend on the use of
the slicer and the kind of products being cut.
This operation must only be carried out by
qualified personnel.
The blade must be replaced when its
diameter is 10 mm less than when original
(see 3.1.2).
WARNING:
REPLACEMENT OF THE BLADE IS
A DANGEROUS OPERATION.
IF THE CUT IS INADEQUATE
AFTER SHARPENING, REPLACE
THE STONES. CONTACT
AVERY BERKEL FOR
ASSISTANCE.
Sharpening operation
Note:
Sharpening must be performed during
manual operation.
WARNING:
WEAR PROTECTIVE GLOVES.
For correct sharpening of the blade follow
these instructions:
1. Clean the blade to remove any greasy
residue, as in 3.1.5.
2. Make sure that the machine is off.