Setting the IP Address Using the ARP/Ping Method
Complete the following steps to configure the camera to use a specific IP address:
Note: The ARP/Ping Method will not work if the Disable setting static IP address through ARP/Ping
methodcheckbox is selected in the camera's web browser interface. For more information, see the
AvigilonHighDefinitionH4andH5IPCameraWebInterfaceUserGuide.
1. Locate and make note of the MAC Address (MAC) listed on the Serial Number Tag for reference.
2. Open a Command Prompt window and enter the following commands:
a. arp -s <NewCameraIPAddress><CameraMACAddress>
For example: arp -s 192.168.1.10 00-18-85-12-45-78
b. ping -l 123 -t <NewCameraIPAddress>
For example: ping -l 123 -t 192.168.1.10
3. Reboot the camera.
4. Close the Command Prompt window when you see the following message:
Reply from <New Camera IP Address>: ...
Setting the IP Address Using the ARP/Ping Method 26

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avigilon 2.0C-H5A-IRPTZ-DP40-WP and is the answer not in the manual?

Avigilon 2.0C-H5A-IRPTZ-DP40-WP Specifications

General IconGeneral
BrandAvigilon
Model2.0C-H5A-IRPTZ-DP40-WP
CategorySecurity Camera
LanguageEnglish

Related product manuals