FREQUENTLY-USED FUNCTIONS
22
5.3.2 Detection Timer
Click “DETECTION”. In “DETECTION TIMER”, select “ON” to enable record timer, and
select the day and time for this function.
SCHEDULE SETTING
RECORD
DETECTION TIMER ON
DETECTION
0 2 4 6 8 10 12 14 16 18 20 22 24
SUN
MON
TUE
WED
THU
FRI
SAT
EXIT
X axis
0 ~ 24 hours. Each time bar is 20 minutes.
Y axis
Monday ~ Sunday.
5.4 Detection Setting
Right-click to display the main menu, and select “ADVANCE CONFIG” “DETECTION”.
ADVANCE CONFIG
C A NE RA CH1 CH2 CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
CH11 W
X
DETECTION LS 07
ALERT SS 03
NETWORK TS 02
SNTP DET OFF
DISPLAY ALARM OFF
RECORD AREA EDIT
REMOTE
EXIT
1) LS (Level of Sensitivity)
“LS” is to set the sensitivity of comparing two different images. The smaller the
value is, the higher sensitivity for motion detection. The highest sensitivity setting is
00, and the lowest sensitivity setting is 15. The default value is 07.
2) SS (Spatial Sensitivity)
“SS” is to set the sensitivity for detecting the size of one object (the number of the
grids) on the screen. The smaller the value is, the higher sensitivity for motion
detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The
default setting is 03.