Checking the firmware
Firmware is so ftware tha t determin es the functionality of network devices. One of your first actions when troubleshooting a problem
should be to check the current firmware version. The latest version may contain a correction that fixes your particular problem. The
current firmware version in the Axis product is displa y ed in the page Setup > Basic Setup and in Setup > About.
Upgrading the firm ware
When you upgrade the product with the latest firmware from Axis website, the product receives the late st functionality available.
Always read the upgrade instructions and release notes availab le with eac h new releas e, before upgrading the firmw are.
To upgrade, follow these instructions:
1. Save the firmware file to your computer. The latest version of the firmware is available fre e of charge from Axis website
at www.axis.com/techsup
2. Go to Setup > System Options > Maintenance in the products web pages.
3. Under Upgrade Server, click Browse and locate the file on your computer. Click Upgrade.
After starting the upgrade process, always w ait at least 5–10 minutes before restarting the p roduct, even if you suspect the
upgrade has failed.
AXIS Camera Management can be used for multiple upgra des . See www.axis.com for more information.
Note
• Your dealer reserves the right to charge for any repair attributable to faulty upgrade by the user.
•Preconfigured and customized settings are saved when the firmw are is upgraded (providing the features are available in
the new firmware) although this is not guaranteed by Axis Communications AB.
Emergency recovery procedure
If pow
er or network connection is lost during the upgrade, the process fails and the product becomes unresponsive. Flashing red Status
indicator indicates a failed upgrade. To recover the product, follow the steps below. The serial number is found on the product’s label.
1. In UNIX/Linux, type the fol low ing from the command line :