AXIS P3301 Fixed Dome Network Camera
Hardware overview
Caution
To protect the product against power surges, a shielded network cable (STP) must be used between the product and the
network switch. Ensure that the network switch is properly grounded.
Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).
Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker
with a built-in amplier. A stereo connector must be used for the audio out.
Control button - The control button is used for:
ConnectingtoanAXISVideoHostingSystemservice.Seepage 34. To connect, press and hold the button for about
1 second until the Status LED ashes gr een.
ConnectingtoAXISInternetDynamicDNSService. Seepage 34. To connect, press and hold the button for
about 3 seconds.
Resetting the product to factory default settings. See page 40.
Power connector - Mini DC connector
I/O connector
Note
For technical specications, se e page 46.
I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notications.
In addition to an auxiliary power and a GND pin, the I/O terminal connect
or provides the interface to:
Digital output For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface, output b uttons on the Live View page or by an Action Rule. The
output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.
Digital input An alarm input for connecting devices that ca n toggle between an open and closed circuit, for
example: PIRs, door/window contacts, glass break detectors, e tc. When a signal is received the state changes and
the input becomes a ctive (shown under System Options > Ports & Devices).
Function Pin Notes
Specications
GND
1
Ground
3.3 V DC Power
2
Can be used to power auxili ary equipment.
Note: This pin can only be used as power out.
Max load = 50 mA
Digital Input
3
Connect to GND to activate, or leave oating (unconnected)
to deactivate.
0to+40VDC
Digital Outpu
t
4
Internal connection to ground when activated, oating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection aga inst voltage transients.
Max l oad =100 mA
Max voltage = +40 V DC
5