5-8
Chapter 5. ADVANCED OPERATION
*3 This item can be set only when other than "0: Not used" is selected at the flowrate alarm setup type C- 15 in the function
setup.
*4 This item can be set only when other than "0: Not used" is selected at the event output type assignment C-07 and C-08
in the function setup.
*5 This item can be set only when "0: User setting" is selected at gas type selection C- 18 in the function setup.
*6 This item can be set only when "8: Instantaneous PV upper limit event, 9: Instantaneous PV lower limit event1 and 10:
Instantaneous PV lower limit event 2" is selected for the C-07 and C-08 event output type assignment in the function
setup.
*7 This item can be set only when "1: Function enabled" is selected for the C-28 analog optional scaling function in the
function setup.
*8 This item can be set only when "11: Integrated flowrate event" is selected at the event output type assignment C-07 and
C-08 in the function setup, or when "1: Function enabled" is selected at the valve automatic shut-off function C- 13.
*9 This item can be set only when "1: Function enabled" is selected at the PV forced zero function C-29 in the function
setup.
*10 This item can be set only if suitable limit type is selected for the C-35 SP limit function in the function setup.
*11 The factory setting and setting range becomes the flowrate obtained by multiplying the full scale flowrate by the
percentage in parentheses. (The factory setting and setting range vary according to the gas type.)