www.bal dormotion.com
Basic Installation 3-17MN1901
3.5.3 Motor cable pin configuration - Baldor linear motors
The following table shows the core colors used in a typical Baldor linear motor cable set, part
number A Y1763A00:
Signal name
Motor cable wire color
Motor U Black
Motor V Red
Motor W White
Motor ground Green
Thermal switch Blue
Thermal switch Orange
Signal name Hall cable wire color
Hall 1 (U) White
Hall 2 (V) Red
Hall 3 (W) Black
Hall ground Green
Hall +5VDC Brown
3.5.4 Sinusoidal filter
A sinusoidal filter is used to provide a better quality waveform to the motor, reducing motor noise,
temperature and mechanical stress. It will reduce or eliminate harmful dV/dt values (voltage rise
over time) and voltage doubling effects which can damage motor insulation. This effect occurs
most noticeably when using very long motor cables, for example 30m (100 ft) or more. Baldor
motors intended to be used with drives are designed to withstand the effects of large dV/dt and
overvoltage ef fects. However, if very long motor cables are unavoidable and are causing
problems, then a sinusoidal filter may be beneficial.