4.4 The Output UDT (UDT_BNI004A_Outputs_40_27_041) consists of all outputs associated with the
BNI004A block. A description of this UDT and its function is included here:
4.4.1 Data – this is a single 16-bit INT register that contains all discrete output data bits.
4.4.2 Restart – this is a single 16-bit INT register that contains all discrete Restart bits. A Restart bit
must be toggled following a detected short-circuit event.
4.4.3 Display_RED – this Boolean value transitions the Red LED display on the BNI004A block.
4.4.4 Display_GREEN – this Boolean value transitions the Green LED display on the BNI004 block.
4.4.5 Display_LOCK – this Boolean value locks the display and prevents the user or PLC from
changing the display. While this bit is “high” or ON, a key icon will be indicated on the display.