B&C Electronics CL 7685
Operator’s Manual - Rev. C - 05/05
- 31
Automatic cleaning function (AUTO CLEAN)
_
|NEXT CYCLE:24.0h|
24.0 h: time to the next cleaning cycle
[MODE] to stop the procedure and to go back to D6
[/\]+[\/]+[ENT] press the 3 keys to set to zero the time to the next cleaning cycle
3B. [ENT] to turn the unit to the WAITING/START auto clean
_
|CLEAN C.:WAITING| (START)
WAITING: the unit is awaiting to start a new Clean Cycle
[MODE] to stop the procedure and to go back to D6
4B. [/\] [\/] to select START or WAITING
5B. [ENT] to confirm selection
- If START is selected the unit go back to D0 and a manual Clean Cycle
starts without modify the time of the automatic Clean Cycle.
- If WAITING is selected the unit turn to the period of repetition
calibration (see steps 6B and 7B).
_
|REPETITION:24.0h|
24.0 h: period of repetition
[MODE] to stop the procedure and to go back to D6
6B. [/\] [\/] to select the time value
7B. [ENT] to confirm and to go back to D6
IMPORTANT NOTE: during the calibration procedure the microcomputer turn the unit to the main