B&C Electronics CL 7685
Operator’s Manual - Rev. C - 05/05
- 30 –
5. [/\] [\/] to select the value
6. [ENT] to confirm and to go to the delay time selection
_
|CAL AL D: 25.0s | Delay time calibration
D 25.0 s: actual delay time
[MODE] to stop the procedure and to go back to D5
7. [/\] [\/] to select the value
8. [ENT] to confirm and to go back to D5
MESSAGE FUNCTION
_
| " UPDATE " | the new data have been memorized
6.6 CLEANING FUNCTION CALIBRATION
1. [MODE] to go to
_
D6 |CLEANING OFF | (MANUAL CLEAN/AUTO CLEAN)
CLEANING OFF: cleaning function disabled
MANUAL CLEAN: manual cleaning function
AUTO CLEAN: automatic cleaning function
2. [CAL] to access to the calibration sequences
(only for MANUAL CLEAN or AUTO CLEAN)
Manual cleaning function (MANUAL CLEAN)
The instrument will show the following display:
_
|CLEAN C.:WAITING| (START)
WAITING: the unit is awaiting to start a new Clean Cycle
[MODE] to stop the procedure and to go back to D6
3A. [/\] [\/] to select START or WAITING
4A. [ENT] to confirm selection
- If START is selected the unit go back to D0 and a new Clean Cycle
starts
- If WAITING is selected the unit go back to D6.