4. Lamp & Lamp House
5
Image 4-21
8. Install the side cover of the Lamp House and fasten the three quarter turn screws (reference 4 image 4-22) of the cover.
Note: Please e nsure that the quarter turn screws turning wires are ush with the cover or interferenc
e will occ ur while inserting
the Lam p House into the projector.
4
Image 4-22
9. Secur e the xenon lam p cathode with the hexa gon s ocket head cap screw (reference 1 image 4-23), spring washer (reference 2
image 4-23) a nd plain wa sher (reference 3 image 4-23). Fasten t he screw with a torque of 5Nm(3,7 lbf*ft). Use a torque wrench
with a 5 mm Allen socket.
Caution: Make sure that both pins (reference 11 image 4-23) of the c athode adapter remain engaged in the foreseen slots.
5 Nm
5
m
5 Nm
3
2
1
11
Image 4-23
CAUTION: The “LAMP INFO” parameters wh ich are s tored on a chip inside the Lamp House MUS T be updated
after each installation of an xenon lamp inside the Lam p House. Neglecting this update will result in poor
performance and short life tim e o f the xe non lam p.
38 R5905067 DPXK-19B/23B/P 17/09/2012