7 Technical data
Technical data - electrical ratings
Voltage supply 12...265 VDC and 20...265 VAC
Power consumption 3 W
Sensor supply 24 V ±3 V % / max. 30 mA
Display LED, 7-segment display (with 100 unit
stickers for front)
Number of digits 4-digits
Digit height 10 mm, 20 mm
Display range -9999...9999 (numerals 14 mm high)
-1999...9999 (numerals 20 mm high)
(-oUE or oUE to signal overflow, oUE
to signal sensor break)
Display refresh 50 ms
A/D transformer Principle ∑∆
Resolution 16 bit
Measuring rate 20/s
Measuring accuracy ±(0.1%+3digit)
Temp. coeffic. 100ppm/°C
Analog input Current, voltage, potentiometer, tem-
perature, resistance, measurement
Programmable Measuring range
parameters Display range can be linearised
Decimal point
Relay outputs with time delay or
hysteresis
Analog input
Limits Without, 2
Data memory >10 Jahre in EEPROM
Outputs relay 2x change-over contact, floating
Standard Protection class II
DIN EN 61010-1 Overvoltage category II
Pollution degree 2
Emitted interference DIN EN 61000-6-3
Interference immunity DIN EN 61000-6-2