Parameter
46 V-Controller (BUS 6 VC)
5.03047.01 Baumüller Nürnberg Electronic GmbH & Co. KG
P058 N integral action time
Integral action time (T
N
) of Uzk controller.
P087 ES Uzk nominal value
This parameter sets the nominal intermediate circuit voltage set value of the BUC.
P047 N Uzk additional set value
P050 N Uzk set value
This parameter sets the intermediate circuit voltage.
P051 N Uzk actual value
Actual value of the intermediate circuit voltage.
P052 N Uzk controller output
This parameter displays the set value of the Uzk controller.
P054 I max. feed back current
Limiter of the maximum feed back mains current
P055 I max. feed-in current
Limiter of the maximum feed-in (supply) mains current.
P060 N Uzk control deviation
This parameter displays the control deviation of the Uzk controller at the moment.
P061 N Uzk limiter control deviation
If the value falls below the maximum deviation set by this parameter, the function module
transmits the message set value reached (bit no. 12 in N state P059 is set).
P204 N Uzk set max.
Limiter of the maximum intermediate circuit voltage set value.
P205 N Uzk set min.
Limiter of the maximum intermediate circuit voltage set value.