Parameter
86 V-Controller (BUS 6 VC)
5.03047.01 Baumüller Nürnberg Electronic GmbH & Co. KG
7.17 Service Interface
Function
The service interface allows communication with the PC operating program. The BASS protocol is op-
erated via the RS 232 interface X23.
The address of each drive is set in binary code at the controller front via DIP switch. Bit no. 0 thus cor-
responds to switch 1, bit no. 1 to switch 2 etc.
The RS 232 interface is constructed potential-free, the operating mode is full-duplex.
Data format: 8 data bits, 1 stop bit, no parity
Transmission speed: 9600 baud
Transmission format: ASCII
Communication PC drive
Example 1: Set P002 to 75 %
Example 2: Read P051