Parameter
V-Controller (BUS 6 VC) 55
Baumüller Nürnberg Electronic GmbH & Co. KG 5.03047.01
7.8 New BUC Parameter
Parameter overview
Parameter description
P600 M Uzk threshold
Reaches the intermediate circuit voltage the set value during the charging and P623 (mains
jitter) < P624 (jitter limit), the main contactor is enabled (charging finished).
P601 M MC switching time
This time is started after the contactor is switched on. If this time is run up the digital output 2
(X26:22 ready for pulse enable) changes to high.
Parameter Name Range
min. ... max.
Unit Display
only
P600 M Uzk threshold 117 .... 1000 V
P601 M MC switching time 10 ... 10000 ms
P602 M pre-control time 1 ... 10000 ms
P610 MM Uzk actual 117 ... 1000 V
!
P611 MM Uzk actual smoothed 117 ... 1000 V
!
P612 MM Uzk filter time 0,0 ... 200,0 ms
P616 BUC control word 0000 ... FFFF -
!
P617 MM CC counter 0 ... 65535 -
!
P618 MM period time mains 0,000 ... 65,535 ms
!
P619 MM period smoothed 0,000 ... 65,535 ms
!
P620 MM PLL display smoothing 0,000 ... 1000,0 ms
!
P621 MM mains frequency 0,00 ... 655,35 Hz
!
P622 MM no. of mains faults -32767 ... 32767 -
!
P623 MM mains jitter -180,0 ... 180,0 Grad
!
P624 MM jitter limit 0,0 ... 30,0 Grad
P625 MM Rho offset 0,0 ... 200,0 ms
P626 MM Rho -32767 ... 32767 -.
!
P627 I current delta_max -100,00 ... 100,00 %
P628 I delta ISQ -199,99 ... 199,99 %
!
P629 I delta ISD -199,99 ... 199,99 %
!
P630 I IQ set smoothing time 0,0 ... 500,0 ms
P631 MM U mains alpha -199,99 ... 199,99 %
!
P632 MM U mains beta -199,99 ... 199,99 %
!
P633 MM mains voltage eff. 0,0 ... 640,0 V
!
P634 MM effective power -3276,7 ... 3276,7 kW
!