Parameter
78 V-Controller (BUS 6 VC)
5.03047.01 Baumüller Nürnberg Electronic GmbH & Co. KG
7.14 Analog Outputs
Function
The module „analog outputs“ transmits freely selectable (and scalable) parameter values to an analog
output via a 12-bit digital-to-analog converter. It is possible transmitting 32-bit parameter either the low
word to one channel or to channel 1 the low word and to channel 2 the high word of the 32 bit parameter.
At a voltage range of ± 10 V the output current should not exceed 1 mA.
Parameter overview
NOTE
The following sequence must be observed for writing the parameters:
1.AA x source-Pxxx
2.AA x offset
3.AA x scaling
Parameter Name Range
min. ... max.
Unit Display
only
P338 AO state 0 ... FFFF -
!
P337 AO test value -10,000 ... +10,000 V
P330 AO 1 source Pxxx 0 ... 700
P331 AO 1 offset -100000 ... +100000 Dig
P332 AO 1 scaling -25000 ... +25000 Dig/V
P334 AO 2 source Pxxx 0 ... 700
P335 AO 2 offset -100000 ... +100000 Dig
P336 AO 2 scaling -25000 ... +25000 Dig/V