Examples:
Input voltage AI-value [%] * MAX_value
target parameter value
Examples of characteristic curves:
scaling = 1; offset = 0%; threshold value = 0%;
Unsigned target parameter:
10 V 100 % * MAX_value
5 V 75 % * MAX_value
0 V 50 % * MAX_value
- 5 V 25 % * MAX_value
- 10 V 0 % * MAX_value
Signed target parameter:
10 V 100 % * MAX_value
5 V 50 % * MAX_value
0 V 0 % * MAX_value
- 5 V -50 % * MAX_value
- 10 V -100 % * MAX_value
scaling = 2; offset = -100%; threshold value = 0%;
Unsigned target parameter:
10 V ( 100 % * MAX_value
5 V ( 50 % * MAX_value
0 V ( 0 % * MAX_value
- 5 V ( 0 % * MAX_value (limitation !)
- 10 V ( 0 % * MAX_value (limitation !)
Signed target parameter:
10 V ( 100 % * MAX_value
5 V ( 0 % * MAX_value
0 V ( -100 % * MAX_value
- 5 V ( -100 % * MAX_value (limitation !)
- 10 V ( -100 % * MAX_value (limitation !)
scaling = 1; offset = 0; threshold value = 10.1%;
Unsigned target parameter:
10 V ( 100 % * MAX_value
5 V ( 75 % * MAX_value
0 V ( 50 % * MAX_value
-5 V ( 25 % * MAX_value
- 9 V ( 0 % * MAX_value (threshold !)
- 10 V ( 0 % * MAX_value
Signed target parameter:
10 V ( 100 % * MAX_value
5 V ( 50 % * MAX_value
1 V ( 0 % * MAX_value (threshold !)
- 1 V ( 0 % * MAX_value (threshold !)
- 5 V ( -50 % * MAX_value
- 10 V ( -100 % * MAX_value
Unsigned target parameter
S
igned target parameter
0+10
+10
-10
-10
Threshold
Threshold
Threshold
50
100
+100
-100
AI_value [%]
AI_value [%]
U [V]
U [V
]
in
in
Offset = 0 %; scaling = 1 Offset = 0 %; scaling = 1