Parameter
76 V-Controller (BUS 6 VC)
5.03047.01 Baumüller Nürnberg Electronic GmbH & Co. KG
Basics of equation:
Maximum target parameter value: MAX_value
Analog input voltage: U
in
{ -10 ... +10 V };
U
inmax
= +10V;
Equation:
! Unsigned parameters:
if AI_value > 100 % → AI_value = 100 %
! Signed parameters:
if AI_value > 100 % → AI_value = 100 %
if AI_value < -100 % → AI_value = -100 %
Both for signed and unsigned parameters
|AI_value [%]| < threshold value [%] then AI_value = 0 %
Written to the target parameter:
AI_value %[]
U
in
V[] 10V+
2U
inmax
V[]⋅
----------------------------------
*Scaling*100%+Offset=
AI_value %[]
U
in
V[]
U
inmax
V[]
--------------------------
*Scaling*100%+Offset=
Value t etarg
AI_value[%]
100%
--------------------------------