Parameter
V-Controller (BUS 6 VC) 75
Baumüller Nürnberg Electronic GmbH & Co. KG 5.03047.01
P279 AI 1 scaling
P286 AI 2 scaling
These parameters enable scaling of the analog input variable.
The output values (see parameters P283, P290, P297, P304) of unsigned parameters are 0
till +100 % and of signed parameters are -100 % till +100 %. Which analog input voltage this
maximum values achieved depends on the scaling factor.
P280 AI 1 target Pxxx
P287 AI 2 target Pxxx
The receiver address for the output value can be set via this parameter.
P281 AI 1 offset
P288 AI 2 offset
These parameters can compensate for a possibly existing input voltage offset.
P282 AI 1 threshold value
P289 AI 2 threshold value
The sensitivity of the inputs can be set via the threshold values.
P283 AI 1 value
P290 AI 2 value
The AI value displays the respective current output value taking scaling and offset compen-
sation into consideration.
NOTE
No target parameter number check is carried out.