7.12 Set Value Generator
Function
The module creates a plateau set value for each of the 4 time zones. Both the plateau amplitude and the
output time interval per zone can be allocated parameters. The amplitudes are relative and are standar
-
dised by means of the min./max. receiver values. On termination of the last time zone the first time zone
starts again. Each time the controller is enabled the set value generator is newly started in zone 1. When
leaving the state „operation enabled“ (P121), the set value generator is stopped.
Thus e.g. the following speed set value graph can be created:
Parameter overview
Parameter Name Range
min. ... max.
Unit Display
only
P150 SVG state 0000 ... FFFF
!
P140 SVG target Pxxx 0 ... 700
P141 SVG output - 100,00 ... + 100,00 %
!
P142 SVG set value 1 - 100,00 ... + 100,00 %
P143 SVG set value 2 - 100,00 ... + 100,00 %
P144 SVG set value 3 - 100,00 ... + 100,00 %
P145 SVG set value 4 - 100,00 ... + 100,00 %
P146 SVG time 1 0,001 ... 60,000 s
P147 SVG time 2 0,001 ... 60,000 s
P148 SVG time 3 0,001 ... 60,000 s
P149 SVG time 4 0,001 ... 60,000 s