Parameter
V-Controller (BUS 6 VC) 87
Baumüller Nürnberg Electronic GmbH & Co. KG 5.03047.01
BOF # (23
hex
)
Address of the drive 0
dec
to 255
dec
(00
hex
to FF
hex
)
Control
Parameter number Hexadecimal value of the parameter number as an ASCII character
Data Element, error type
Number are given as hexadecimal numbers and are transmitted as ASCII char-
acters
The half-byte with the highest value is transmitted first
Really text begins with two words following one after another which contains the
length of the text:
Checksum Sum of the hexadecimal values of all ASCII characters without BOF and EOF. Any over-
flow is also added (234
hex
36
hex
)
EOF <CR> <LF> (0D
hex
, 0A