EasyManua.ls Logo

Bavaria Vision 46 - Gas System Inspection

Bavaria Vision 46
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Owner‘s manual
42
6.9.4. Inspection of the gas system
TesttheLPGsystemforleakageregularly.Checkallconnectionsforleakageby:
1. Routine checks with a leak detector
2. Manualleaktesting:Testingwithsoapywaterordetergentsolution(withappliance-burnervalvesclosedand
cylinderandsystemvalvesopen)
Caution
» LPGlinesmustbeinspectedregularly,atleastannually,andreplacedifanydeteriorationis
found.
» Ifleakageispresent,closethecylindervalveandhavethesystemrepairedbeforefurtheruse.
Gassystemrepairsshouldonlybeexecutedbyacompetentperson.
» To be able to check the gas connections at the stove the front covers must be removed.
Danger
» Donotsmokeoruseopenamewhilecontrollingforleakages.
» DonotsmokeoruseopenamewhenreplacingLPGcylinders.
» Do not use gas cylinders with damaged threads. Danger of gas leakage.
» Do not use grease or sealants at the valves.
i
Note:Gassystemtightnesstest
With appliance valves closed!
» Opencylindervalve.closecylindervalveagain
» Waituntilthemanometer(inthepressurisedline)hassettledonaconstantreading
» Observethemanometerfor3minutes
» Thereisnoleakifthepressurereadingisconstant-shouldthepressuredrop,thereisaleak
Closethevalveatthebottle,havetheleakrepaired-donotusethegassystem,beforeithas
been repaired.