Tab.52 Configuration menu
Parameter
number
Parameter Description Factory set
ting
5710 Temps / mode CH1 Activation of heating circuit 1:
Off
On
On
5715 Temps / mode CH2 Activation of heating circuit 2:
Off
On
Off
5721 Temps / mode CH3 Activation of heating circuit 3:
Off
On
Off
5730 Hot water sensor Selection of the domestic hot water sensor:
Hot water sensor B3 : Domestic hot water sensor for tank
Thermostat : The sensor used for domestic hot water is a thermostat
Hot water
sensor B3
5731 HW controlling
element
Type of actuator for controlling the domestic hot water requirement:
No charging request : No function
Charging pump : Domestic hot water loading is done with a pump.
Diverting valve : Domestic hot water loading is done with a bypass
valve.
Diverting
valve
10 Settings
84 POWER HT + 7702630 - v02 - 11082018

Table of Contents

Other manuals for Baxi POWER HT+ Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baxi POWER HT+ Series and is the answer not in the manual?

Baxi POWER HT+ Series Specifications

General IconGeneral
ModelPOWER HT+ Series
CategoryBoiler
Installation TypeWall-mounted
Heat Exchanger MaterialStainless Steel
Warranty2 years
Fuel TypeNatural Gas
Control SystemIntegrated Control
Ignition TypeElectronic

Related product manuals