Information Description Unit
Outside temp min
Minimum outside temperature value memorised
Important
The outside sensor must be connected.
°C
Outside temp max
Maximum outside temperature value memorised
Important
The outside sensor must be connected.
°C
Hot water temp 1 Domestic hot water temperature
Important
The value displayed comes from the sensor on the
boiler's domestic hot water circuit.
°C
Collector temp 1 Instantaneous temperature of the solar panel sensor (when asso
ciated to a solar system)
°C
State central heating CH1 Operating mode of heating circuit 1
State central heating CH2 Operating mode of heating circuit 2
State central heating CH3 Operating mode of heating circuit 3
State hot water Domestic hot water circuit operating mode
State boiler Boiler operating mode
State solar Indicates solar running (when associated to a solar system) -
Telephone customer service Telephone number of the After Sales Service
10.1.3 List of user parameters
Tab.39 Structure of the user menu
Menu Feature
Set time and date Setting the time and date
Operator section Change Language
Programming lock
Time program
Time hot water
Predefined or custom programs with a maximum of 3 comfort or domestic
hot water production ranges for each 24 hours
Holiday Settings Eco heating or frost protection mode for a defined period
Temps / mode CH1
Temps / mode CH2
Temps / mode CH3
Choice of Comfort/Eco/Auto/Standby mode for each heating circuit with re
duced or comfort temperature
Tab.40 Set time and date menu
Parameter number Parameter Description
1 Hours / minutes Setting the time
2 Day / month Setting the day and the month
3 Year Setting the year
Tab.41 Operator section menu
Parameter number Parameter Description Factory setting
20 Change Language Setting the interface language English
27 Programming lock Setting the programming lock
Off: the parameters can be displayed and modified
On: the parameters can be displayed but cannot be modi
fied
Off
10 Settings