– 25 –
COLOR CODE DESCRIPTION Action
Green E85 Close Loading Door Close door. If door is closed, contact a Baxter authorized servicer.
Yellow E5 Heating Error Manual reset high temperature limit tripped. Heat disabled.
• Bake/cook cycle can continue but heat is disabled. Bake/cook
time may need to be extended.
• Contact a Baxter authorized servicer to resolve issue.
Yellow E6 Heating Error Manual reset rollout switch tripped. Heat is disabled.
• Bake/cook cycle can continue but heat is disabled. Bake/cook
time may need to be extended.
• Contact a Baxter authorized servicer to resolve issue.
Yellow E10 Heating Error Oven is heating slow. If burner is not running, try opening and
closing the loading door.
• Bake/cook cycle can continue but heat is disabled. Bake/cook
time may need to be extended.
• Contact a Baxter authorized servicer to resolve issue.
Yellow E35 Rack Rotation
Motor Error
No rotation detected. Open loading door and check for rack/pan
jam.
• If there is no rack/pan jam or problem continues, contact a Baxter
authorized servicer.
Yellow E75 Hood Ventilation
Error
Hood switch input not detected. Heat disabled.
• Bake/cook cycle can continue but heat is disabled. Bake/cook
time may need to be extended.
• Contact a Baxter authorized servicer to resolve issue.
Red E8 Heating Error Temperature sensor failure. Heat disabled.
• Contact a Baxter authorized servicer to resolve issue.
Red E9 Heating Error High temperature detected. Shut o gas and/or breakers.
• Contact a Baxter authorized servicer to resolve issue.
Red E15 Convection Fan
Error
Convection fan overheated. Motor timed out and heat disabled.
• Contact a Baxter authorized servicer to resolve issue.
Red E25 Rack Lift Motor
Error
Up switch not detected. Motor timed out.
• Contact a Baxter authorized servicer to resolve issue.
Red E26 Rack Lift Motor
Error
Down switch not detected. Motor timed out.
• Contact a Baxter authorized servicer to resolve issue.
Red E27 Rack Limit Switch
Error
Detecting up and down limits at the same time. Motor timed out.
• Contact a Baxter authorized servicer to resolve issue.
Red E76 Hood Ventilation
Error
Possible hood switch failure. Heat disabled.
• Contact a Baxter authorized servicer to resolve issue.
Red E95 Electronics
Overheated
Board temperature exceeded limit.
• Contact a Baxter authorized servicer to resolve issue.