Additional functions with CentronicPLUS/ Centronic
Activating/deactivating the additional fabric untensioning function
The "to upper stop" limit position must be set for the fabric untensioning function.
On delivery, the fabric stretching function is deactivated on tubular drives with a diameter of 35 mm, and is activated on tubular
drives with diameters of 45 mm.
Activating/deactivating the fabric untensioning function with a CentronicPLUS transmitter
Select the required receiver as described in the chapter Selection of the receiver for
the setting mode [}12].
Open the shading solution to the upper limit position.
3s
Then press the programming button again, and also the STOP and buttons for ap-
prox. 3seconds.
▻
The tubular drive confirms.
▻
The transmitter confirms with a purple rotating light at the LED ring.
►
The fabric untensioning function is now activated/deactivated.
3s
Then press the programming button for 3seconds to change to normal mode.
►
The LED ring goes out.
Activating/deactivating the fabric untensioning function with a Centronic transmitter (master
transmitter)
Open the shading solution to the upper limit position.
3s
Then press the programming button again, and also the STOP and buttons for ap-
prox. 3seconds.
▻
The tubular drive confirms.
►
The fabric untensioning function is now activated/deactivated.
Programming the run times
This function is available with all CentronicPlus EasyControl transmitters and with
Centronic devices only equipped with "MemoControl" transmitters from the Becker range
of control units. Both limit positions must be set before the Memo function is set.
This receiver can save a switching time for one and one cycle respectively. The drive command saved in this way is executed
automatically every 24 hours when the Memo function is activated. Run times previously programmed are overwritten, irrespective
of which transmitter the programming was carried out from.
The tubular drive must be in the upper limit position to program the run time, and in
the lower limit position to program the run time.
Wait until the time at which the automatic drive command is to be carried out.
6s
At the desired time, press and hold the relevant travel button until the tubular drive
briefly stops after approx. 6seconds then continues to the limit position.
You can now release the travel button.
►
The receiver has saved the current time for this drive command.
27-en