4.3 Control more than two DCX2496 devices
• First DCX: Connect the USB-RS232
interface with the RS232 plug of the
DCX2496 (rear side)
• Adjust “SETUP ➔ Miscellaneous”
o Set Port = PC ➔ Link
• Enable/Push the RS485 bus “Term” button from the DCX2496 rear side
• Second DCX: Connect the 2
nd
DCX2496
with the first DCX via the RS485
connector
• Adjust “SETUP ➔ Miscellaneous”
o Set Port= LINK (RS485)
• Set the Device Id different to the Id from the first DCX2496
o E.g. Device ID =2
• Disable the RS485 “Term” button from the DCX2496 rear side
• Last DCX: Connect the 3
rd
DCX2496 with
the 2
nd
DCX via the RS485 connector
• Adjust “SETUP ➔ Miscellaneous”
o Set Port= LINK (RS485)
• Set the Device Id different to the other one
o E.g. Device ID =3
• Enable/Push the RS485 “Term” button from the DCX2496 rear side