EasyManua.ls Logo

Beko DRYPOINT M intelligence - Function Testing and Visual Inspection; Changing Filter Element

Beko DRYPOINT M intelligence
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and operation instructions US-EN
28 DRYPOINT
®
M intelligence
7.1.2. Changing lter element
The lter elements must be changed at least every 12 months. To change the lter element: 
1. Close the shut-o valves (1) and open the shut-o valve (2) of the bypass.
2. Hold the top part of the housing, unscrew the housing extension (3) and remove it (4).
3. Remove the spent lter element (5) and dispose of it safely.
4. Insert the new lter element (6).
5. Mount (7) and screw on (8) the housing extension.
6. Open the shut-o valves (9) and close the shut-o valve (10) of the bypass.
7. Apply the new nanolter service label (11).
1
2
1
4
5
3
7
8
6
9
10
9
11
CAUTION
Risk of damage to the environment!
Spent lter elements might contain substances that are harmful to the environment.
Therefore dispose of spent lter elements according to the applicable statutory regulations. 
For more information, see chapter 6. "Dismantling and disposal", page 32.