EasyManua.ls Logo

Belden HIRSCHMANN BRS32 - Page 91

Belden HIRSCHMANN BRS32
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation BRS20/22/30/32/40/42/50/52
Release
12
01/2022
91
EMC interference immunity Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Navy
applications
Railway
applications
(trackside) as per
EN 50121-4
Electrostatic discharge
EN 61000-4-2 Contact discharge ±4 kV ±6 kV ±6 kV
EN 61000-4-2 Air discharge ±8 kV ±8 kV ±8 kV
Electromagnetic field
EN 61000-4-3 80 MHz ... 800 MHz max. 10 V/m
80 MHz ... 1000 MHz max. 10 V/m
800 MHz ... 1000 MHz 20 V/m
80 MHz ... 2000 MHz max. 10 V/m
1.4 GHz ... 2.0 GHz 3 V/m max. 10 V/m
2.0 GHz ... 2.7 GHz 1 V/m 5 V/m
5.1 GHz ... 6.0 GHz 3 V/m
Fast transients (burst) – power supply connection
EN 61000-4-4 ±2 kV ±2 kV ±2 kV
Fast transients (burst) – data line
EN 61000-4-4 ±1 kV ±1 kV ±2 kV
Voltage surges – power supply connection
EN 61000-4-5 line/ground ±2 kV ±1 kV ±2 kV
EN 61000-4-5 line/line ±1 kV ±0.5 kV ±1 kV
Voltage surges - data line
EN 61000-4-5 line/ground ±1 kV ±2 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V 10 V 10 V
Table 27: EMC interference immunity

Table of Contents