46
Installation OCTOPUS OS3
Release
03
08/2020
Supply voltage with the characteristic value HH
Rated voltage 36 V DC ... 48 V DC
Voltage range including maximum
tolerances
25.2 V DC ... 60 V DC
Connection type 5-pin, “L”-coded M12 plug
Tightening torque 5.3 lb-in (0.6 Nm)
Wire diameter AWG16 (1.5 mm²)
a
a. When using the supplied plug.
Power loss buffer >16 ms at 48 V
Overload current protection on the device Non-replaceable fuse
Back-up fuse for each voltage input Nominal rating: max. 20 A
Characteristic: slow blow
Peak inrush current 8 A
Connection for functional ground See “Grounding the device” on page 36.
Current integral I²t <1.5 A²s
Table 18: Supply voltage with characteristic value HH
Supply voltage with the characteristic value PP
Rated voltage PoE 48 V DC
PoE+ 54 V DC
Voltage range including maximum
tolerances
PoE 47 V DC ... 57 V DC
PoE+ 53 V DC ... 57 V DC
Connection type 5-pin, “L”-coded M12 plug
Tightening torque 5.3 lb-in (0.6 Nm)
Wire diameter AWG16 (1.5 mm²)
a
a. When using the supplied plug.
Power loss buffer >10 ms
Overload current protection on the device Non-replaceable fuse
Back-up fuse for each voltage input Nominal rating: 6.3 A
Characteristic: slow blow
Peak inrush current 3.5 A
Connection for functional ground See “Grounding the device” on page 36.
Current integral I²t <0.4 A²s
Max. PoE power Nominally 124 W
Table 19: Supply voltage with characteristic value PP
Supply voltage with characteristic value QQ
Rated voltage 24/36/48 V DC
Voltage range including maximum
tolerances
16.8 V DC ... 60 V DC
Connection type 5-pin, “L”-coded M12 plug
Tightening torque 5.3 lb-in (0.6 Nm)
Wire diameter AWG16 (1.5 mm²)
a
Power loss buffer >10 ms at 24 V
>16 ms at 48 V
Overload current protection on the device Non-replaceable fuse
Table 20: Supply voltage with characteristic value QQ