FULL FUNCTION DISPLAY SPECIFICATIONS
Power Consumption 80 ma. nominal, 110 ma. maximum
during alert (with Receiver)
Operating Temperature Range -20˚ F to 185˚ F (-29˚ C to 85˚ C)
Size 2.8” W x 0.74” D x 1.64” H
(71mm x 19mm x 42mm)
Weight 1.5oz AV (43 gm.)
Operating Humidity 100% non condensing
Function Range
Cold Inflation Pressure 10 – 76 PSI (.70 – 5.20 Bar)
Low Pressure Warning 5 – 92 PSI (.33 – 6.35 Bar)
Pressure Deviation Alert Off – 2 – 20 PSI (.15 – 1.40 Bar)
High Temperature Alert Off – 86 – 248˚ F(30˚ C – 120˚ C)
Slope 10 –160
Units of temperature ˚F ˚C
Units of pressure Bar Psi
Number of tires monitored 20 (10 towing vehicle, 10 towed vehicle)