2. Install the two 90-degree fittings at the cylinder ports. On the
pipe thread side of the fitting it is recommended to use teflon
tape or pipe sealer. DO NOT USE TEFLON TAPE on the JIC
flared end. (See Fig. 10.3 & 10.4 )
3. Install the two standard bulkhead couplers at the outside of
the POWERSIDE RUNWAY adjacent to the power unit.
Tighten securely. (See Fig. 10.5 )
4. Connect hoses as shown below making sure to pass
through the retaining rings. MAKE SURE HOSES ARE KEPT
CLEAR OF CABLES. (See Fig. 10.6, 10.7 & 10.8 )
Fig. 10.3
Fig. 10.4
Fig. 10.5
Fig. 10.7
Fig. 10.6
Fig. 10.8
17